E41-499 · Screw Selection · Screw-Grease Overfill Seal Rupture · ★★
The centralized lubrication system of the screw nut injected too much grease per cycle during automatic greasing (standard 0.5 ml, actual 2 ml); the seal ruptured after 2 weeks and grease leaked out.
The centralized lubrication system (progressive divider) is set to 0.5 ml per port per cycle (greasing every 4 h). A divider fault (stuck spool) raised the per-port charge from 0.5 ml to 2 ml (×4). Excess grease accumulated inside the nut, raising pressure (about 0.5 MPa). Under 0.5 MPa the lip seals at both ends of the nut (skeleton oil seals, NBR) flipped open and the seals popped out of their grooves. Once dislodged, the grease was flung out through the seal gap by centrifugal force from the rotating screw (screw speed 2000 rpm, centrifugal force ≈ 5 N), leaving visible oil stains on the floor after each run. The internal grease fill rose from the normal 60% to 95% (overfilled); the excess grease was churned by the balls (churning power ×4), increasing heat and raising the nut temperature from 40 ℃ to 55 ℃.
① Periodically check the centralized lubrication grease volume (monthly; collect old grease from the relief port)\n② Clean the progressive divider regularly (every 6 months to prevent spool sticking)\n③ Set grease volume per manufacturer recommendation (screw nuts generally 0.2–0.5 ml/point/cycle)\n④ Use pressure-resistant seals (with spring, withstand 0.5 MPa backpressure)\n⑤ Provide a grease relief port on the nut (allows excess grease to drain, preventing internal pressure rise)
FT_11 Ball Screw Selection