E41-500 · Ball Screw Selection · Machining Center X-Axis Ball Screw Preload Lock Nut · ★★★★
After one year of service the ball screw preload lock nut on the X-axis of a machining center fell off. The ball screw developed about 0.3mm of bending deflection under axial load and lost its accuracy.
The lock nut at the fixed end of the ball screw (M42×1.5 fine thread) is used to apply the preload. Its working preload is about 50kN, and under axial load (cutting force about 5000N) the nut is subjected to axial vibration. The stop washer of the lock nut (external tab stop washer) was not bent over at installation (the washer tab was not folded into the nut groove), so the stop washer lost its anti-loosening function. Under long-term alternating load (about 1000 cutting cycles per day) the nut self-loosened (self-loosening angle about 0.01° per cycle). After one year the nut had rotated about 3.6 turns (0.01°×3.65×10⁵/360° ≈ 10 turns), the preload was completely lost, and the ball screw ran in the un-preloaded state. Under the cutting force (5000N) the ball screw bent, with deflection δ=F×L³/(48×E×I)=5000×1.2³/(48×206e9×π×0.03⁴/64)≈0.0003m=0.3mm. The bent screw interfered with the nut, running resistance increased, and the motor drive current rose from 5A to 8A.
1) The ball screw preload lock nut must use effective anti-loosening measures (bent tab stop washer + thread-locking compound);
2) Mark the nut position after installation (scratch a witness line with paint across the nut and the screw end face so that loosening can be detected);
3) Inspect the lock nut at regular intervals (every quarter; if the witness line has shifted the nut must be re-tightened);
4) Use double-nut locking (main nut + lock nut, giving double anti-loosening);
5) Use hydraulic preload (a hydraulic nut controls the tensioning force precisely and locks reliably).
FT_11_Ball Screw Selection