Weld Deformation of Nut Housing Tilts the Nut (Welded Structure)

E41-503 · Ball Screw Selection · Welded Nut Housing Deformation and Tilt · ★★★★

Problem Symptom

The ball screw nut housing was welded to the bottom face of the table. After welding the bottom face of the housing warped by 0.05mm, the nut tilted by 0.03° after installation, and the ball screw running resistance became uneven.

Root Cause

When the nut housing (Q235 steel plate, 20mm thick) is welded to the table bottom face (30mm thick) the weld seams are concentrated around the housing perimeter (fillet welds, leg height 8mm). The welding heat causes thermal expansion of the housing (about 200℃); on cooling it contracts and produces weld deformation (warpage). The warpage is δ=α×L×ΔT/2=12×10⁻⁶×80×200/2≈0.096mm (about 0.1mm); the measured warpage was 0.05mm. Once the nut is mounted on the warped base it tilts by θ=0.05/80≈0.000625rad≈0.036°. With the nut tilted the axes of the ball screw and nut are no longer parallel, the balls in the nut raceway are subjected to side components of load, and the running resistance is uneven over the full stroke (lowest near the middle, highest at both ends). At a tilt of 0.036° the ball screw running resistance increases by about 15% and the reverse backlash increases by about 0.002mm.

Correct Solution

1) Welding procedure for the nut housing: tack-weld for positioning → symmetric welding → stress-relief annealing after welding;
2) Finish-machine the housing mounting face after welding (mill 0.1mm to restore flatness ≤0.01mm);
3) Or change to bolted connection (the housing is bolted to the table, with no weld deformation);
4) Fit shims between the housing and the nut (stainless steel, 0.05/0.10mm, for levelling adjustment);
5) After installation, measure the ball screw running resistance (resistance variation over the full stroke ≤10%).

Checklist

References

FT_11_Ball Screw Selection

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL