Air Lock in the Grease Line Interrupts Supply to the Linear Guide Carriage

E41-521 · Linear Guide Selection · Air Lock in the Lubrication Line · ★★★

Problem Symptom

When the centralised lubrication system supplied grease to the linear guide carriage, air entered the line and formed an air lock, so grease could not be injected into the carriage. The carriage ran without grease after one week.

Root Cause

When the grease reservoir of the centralised lubrication system (progressive distributor) was replaced, the air in the line was not purged and air entered the supply line. Grease is semi-solid (NLGI#2) and flows poorly, so the bubbles in the grease flow (diameter about 2mm) cannot float out (the yield stress of the grease is about 500Pa and the buoyant force of the bubbles is insufficient to overcome it). The bubbles form a blockage (air lock) in the line and grease cannot pass the region occupied by the bubbles. The carriage received no grease within one week and ran dry. In the dry state the friction coefficient rose from 0.004 to 0.02, the heat generation increased five-fold and the carriage temperature rose from 35℃ to 60℃. After one week slight wear (depth about 0.001mm) appeared on the carriage raceway.

Correct Solution

1) Air must be purged from the line after every reservoir replacement (manually operate the grease pump until fresh grease flows from the discharge port);
2) Fit a bleed valve at the end of the line (open it after each reservoir replacement to bleed the air);
3) Use degassed grease (air content ≤2%, fewer bubbles);
4) Fit a bubble detection sensor in the line (ultrasonic detection of bubbles in the pipe);
5) Install the centralised lubrication line with a slope (gradient ≥1:50 so that bubbles can move to the high point and be vented).