E41-534 · Linear Guide Selection · Grease Thickening Overloading the Grease Pump in Winter · ★★★
In northern winters (-20℃) the grease pump of the centralised lubrication system overloaded and stopped on start-up: the consistency of the grease was too high at low temperature and the pump could not push it.
The centralised lubrication system uses NLGI#2 lithium grease. At -20℃ the consistency rises from NLGI#2 to NLGI#4 and the viscosity increases to about 5000mm²/s. When the plunger of the grease pump (plunger pump, motor power 0.75kW) pushes high-consistency grease the resistance is F=ΔP×A=20×10⁶×π×0.008²≈4021N (pump outlet pressure about 20MPa, plunger diameter 16mm). The motor torque is T=F×p/(2π×η)=4021×0.01/(6.28×0.8)≈8Nm (plunger stroke 10mm). The rated motor torque is 4.8Nm, so 8Nm > 4.8Nm and the motor overloads and stops. The grease cannot be delivered to the guide carriages, and during the winter (three months) the carriages ran without lubrication with accelerated wear.
1) Use a low-consistency grease in low-temperature conditions (NLGI#0/00 grade, good low-temperature flow);
2) Fit a heating device on the grease reservoir (electrical heating belt, keeping the grease temperature ≥0℃);
3) Select a low-temperature type grease pump (motor power increased to 1.5kW, able to push high-consistency grease);
4) Change to oil lubrication in winter (VG32, low-temperature viscosity about 200mm²/s, good flow);
5) Test the low-temperature performance of the grease (per ASTM D1478, start-up torque ≤5Nm at -20℃).
FT_10_Linear Guide Selection