E41-535 · Linear Guide Selection · Guide Bolts Self-Loosening on a High-Speed Feed Axis · ★★★★
After one year of running the guide mounting bolts (M12, 100 pieces) of the high-speed press feed axis (stroke 500mm, frequency 150 cycles/min) retained on average only 60% of the standard torque.
The guide is fixed to the base with 100 M12 bolts tightened to 80Nm, giving a preload of about 25kN per bolt. In the high-speed reciprocating motion of the press feed axis (150 cycles/min = 2.5Hz) the guide is subjected to an alternating acceleration a=ω²×A=(2π×2.5)²×0.25≈61.7m/s²≈6.3g, generating an alternating force F=m×a=100×61.7=6170N (mass of the moving part about 100kg). Distributed over 100 bolts that is only about 62N per bolt, far below the preload (25kN), so it should have no effect. However, the bolts suffer fretting wear under the long-term alternating load (about 0.1μm of fretting per thousand cycles in the thread). After one year, about 4×10⁷ cycles, the thread wear reduced the preload from 25kN to about 15kN (a 40% reduction) and the remaining torque fell to 60% of the standard value (48Nm). Once the bolts loosened the friction fell and the guide shifted slightly under the alternating force (0.005mm); the accumulated displacement moved the guide about 0.5mm away from its initial position after one year. The positioning accuracy degraded from ±0.01mm to ±0.05mm.
1) Use anti-loosening washers for the guide bolts of the high-speed feed axis (Nord-Lock, wedge-locking washers);
2) Apply high-strength thread-locking compound to the bolts (Loctite 262, red);
3) Re-check the bolt torque at regular intervals (every 3 months, re-tighten when the torque falls below 80% of the standard value);
4) Fit locating pins to the guide (two Φ8h6 locating pins per section to prevent transverse displacement);
5) Use grade 10.9 bolts (30% higher fatigue strength than grade 8.8).
FT_10_Linear Guide Selection