E41-134 · Bearing Selection · Continuously Running Induced-Draft Fan Bearing · ★★
After 6 months of continuous operation, the induced-draft fan bearings showed a temperature rise (from 55℃ to 80℃) and increased vibration. Disassembly inspection revealed worn and blackened raceway and roller surfaces, and the grease had dried out.
The bearing was greased only once at the factory, but the fill amount was insufficient (only 15% of the bearing cavity, versus the 33~50% standard). After 6 months of continuous running (about 4320 hours), a small amount of grease was flung out by the rolling elements or leaked slightly through the seal, leaving less than 10% remaining. The raceway surface could no longer sustain an elastohydrodynamic lubricant film (EHL); under boundary lubrication the friction coefficient rose from 0.004 to 0.02, increasing heat generation fivefold. At 80℃, the grease oxidized faster, its base-oil viscosity dropped, and lubrication deteriorated further, ultimately causing wear. The regreasing interval is t=K×(d×n)/C, where K is the regreasing coefficient (0.5 for continuous operation), d is the bore diameter 80 mm, n is the speed 1480 rpm, and C is a constant. Using the formula, t=0.5×(80×1480)/100000≈0.59 year≈7 months. The 6-month failure is close to this calculated value.
① Continuously running equipment must have a scheduled regreasing system in place
② Initial grease fill: 33~50% of the bearing internal space
③ Regreasing interval: t=K×(d×n)/C (continuous operation K=0.5, C=100000)
④ In this case the regreasing interval is about 7 months; regreasing every 6 months is recommended
⑤ Inspect the old grease discharged from the drain port; if discolored or hardened, shorten the regreasing interval
FT_23_Bearing Selection Specification