Knowledge Base › Selection Error Cases › Bearing seizure caused by thermal expansion due to blocked cooling water passage in bearing housing (high-temperature fan)

Bearing seizure caused by thermal expansion due to blocked cooling water passage in bearing housing (high-temperature fan)

E41-135 · Bearing Selection · High-Temperature Fan Bearing Housing · ★★★

Problem Description

The high-temperature fan bearing housing has a water-cooling cavity. After 3 months of operation, the bearing temperature rose from a normal 60℃ to 120℃. Inspection during shutdown found the cooling cavity blocked by scale, with cooling-water flow dropping from 5 L/min to 0.3 L/min.

Root Cause

The bearing-housing cooling cavity is an annular water passage with a 100 mm inner diameter and a 25×10 mm cross section. Tap water (not softened) is used for cooling, with a hardness (CaCO₃ content) of about 200 mg/L. At a cooling-water temperature of 60~80℃, scale precipitates at about 0.1 mm/month. After 3 months the scale thickness is about 0.3 mm, and the passage cross section shrinks from 250 mm² to about 160 mm² (a 36% reduction). As flow drops from 5 L/min to 0.3 L/min, the convective heat-transfer coefficient h falls from 5000 W/m²K to about 200 W/m²K (flow changes from turbulent to laminar), cutting the housing heat-dissipation capacity by 96%. The bearing outer ring expands thermally inside the housing; poor housing heat dissipation raises the outer-ring temperature, reducing the axial clearance from the C3 group 30 μm to nearly zero (negative clearance), clamping the rolling elements and causing a sharp rise in friction torque that leads to thermal runaway.

Corrective Solution

① Cooling water should be softened or purified water (hardness ≤50 mg/L)
② The water passage design should allow easy cleaning (add a cleaning port and drain valve)
③ Clean scale periodically (every 3 months, circulate a 5% citric-acid solution for 2 h)
④ Install a flow switch and temperature sensor (alarm when flow <2 L/min)
⑤ Or use closed-loop cooling (coolant plus heat exchanger, no scale formation)

Checklist

Reference

FT_23_Bearing Selection Specification