E41-223 · Bearing Selection · Continuous-Caster Bearing-Housing Cooling · ★★★★★
The continuous-caster segment bearing housing (exposed to 800℃ radiant heat) suffered frequent bearing burnouts after only 1 month of use. Inspection found the cooling-water cavity completely blocked at a passage bend.
The bearing-housing cooling cavity is an annular water passage: inlet Φ12 mm → annular passage → outlet Φ12 mm. The passage has a 90° sharp bend at the corner (no fillet transition). Impurities in the water (rust/welding slag/scale) deposited at the sharp bend and fully blocked it within 3 weeks. After blockage, cooling-water flow dropped from 8 L/min to 0 L/min and the housing lost cooling. The housing surface temperature rose from 120℃ to 400℃ (radiant heating), and the bearing temperature followed up to 200℃ (far above the bearing-steel tempering temperature of 150℃). Bearing hardness dropped from HRC62 to HRC45, and the raceway underwent plastic deformation (brinelling).
① Cooling-water passage design should avoid 90° sharp bends (use a large-radius arc R≥3D transition)\n② Fit a filter at the inlet (stainless-steel screen, ≥40 mesh)\n③ Check cooling-water flow weekly (flow switch alarms at ≤2 L/min)\n④ Use softened or purified water (reduces scale)\n⑤ Add a thermal-insulation layer to the housing (ceramic fiber 10 mm + stainless-steel reflector plate)
FT_23_Bearing Selection Specification