E41-224 · Bearing Selection · Fan Bearing-Housing Installation · ★★★
The induced-draft fan bearing-housing horizontal vibration rose gradually from 3 mm/s to 16 mm/s (limit ≤7 mm/s). Inspection found 2 of the 4 M24 foundation bolts loose.
The fan bearing housing is fixed to the concrete foundation by 4 M24 foundation bolts with an initial tightening torque of 400 Nm. During operation the fan generates an unbalance centrifugal force F=0.01×m×r×ω²=0.01×500×0.1×(157)²≈1232 N (speed 1500 rpm). The alternating force puts the bolts under tension-compression cycles, causing fretting wear under cyclic load and gradual preload loss. After about 6 months the preload dropped from an initial 120 kN to about 60 kN, and friction from 72 kN to 36 kN, still above the 1232 N excitation force. However, because 2 bolts were not tightened in diagonal sequence during installation (two adjacent bolts were tightened first), their preload was uneven, and loosening started at the bolt with the lowest preload. After 2 bolts came loose, the housing was held by only 2 bolts, vibration intensified, and the remaining 2 bolts also loosened quickly.
① Foundation bolt tightening sequence: diagonal crisscross tightening (in 3 steps, increasing force gradually)\n② Use a torque wrench (M24 torque 400 Nm±5%)\n③ Add double-nut locking plus spring washer\n④ Pour epoxy grout (fill the gap between base and foundation to raise contact stiffness)\n⑤ Regularly check bolt torque (monthly; recheck 1 week after first run)