Cage Interference in the Bearing Housing Deforms the Cage (Bore Machining Error)

E41-539 · Bearing Selection · Cage Interference in the Bearing Housing · ★★★

Problem Symptom

After installation the cage of a bearing (NU2310ECM, with a cage guiding ring on the outer ring) was deformed under load and produced abnormal noise after two hours of running. The housing bore had been machined 0.05mm undersize.

Root Cause

The outer ring guide ring of the NU2310ECM bearing (cage outside diameter Φ105mm) should have a clearance of 0.5~1mm in the housing bore (Φ110H7, +0.035/0). The actual machined bore size was Φ110.00mm (the lower limit of the standard) and the guide ring outside diameter was Φ105mm, giving a clearance of 5mm, which is sufficient. However, the cage guide ring was pressed into the housing bore during installation (an operator error while pressing the bearing into the bore caused the cage guide ring to contact the bore). The cage (brass, hardness HB80) was plastically deformed during pressing (compressed by about 0.3mm). The deformed cage makes poor contact with the cage guiding surface, and because the cage is driven round by the rollers it generates friction heat (about 80W); the temperature rose to 120℃, softening the brass cage and further increasing the deformation. After two hours the cage seized and the bearing locked onto the shaft.

Correct Solution

1) Confirm the clearance between the cage guide ring and the housing bore during installation (should be ≥0.5mm);
2) Inspect the bore size (CMM or bore gauge, confirm it is within tolerance);
3) When installing the bearing ensure the cage guide ring does not touch the bore wall;
4) After installation, rotate the bearing by hand to confirm the cage runs without friction (there should be no abnormal resistance);
5) A deformed cage requires bearing replacement (the cage cannot be repaired).

Checklist