MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Selection Error Cases › Excessive Interference on
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Excessive Interference on the Shaft Cracks the Inner Ring (Thin Section Bearing)

E41-538 · Bearing Selection · Inner Ring Cracking from Excessive Interference on a Thin Section Bearing · ★★★★

Problem Symptom

A thin section bearing (61810, wall thickness 3mm) was interference fitted to the shaft (Φ50m6, interference 0.025~0.048mm) and the inner ring developed a longitudinal crack after installation.

Root Cause

The thin section bearing 61810 (bore 50mm, outside diameter 65mm, wall thickness 7.5mm) has a wall thickness to bore ratio of 7.5/50=0.15, which makes it a thin section bearing. The maximum interference of the m6 fit (+0.025/+0.048mm) is 0.048mm. The circumferential stress produced in the inner ring during interference mounting is σ_t=E×Δ/(2r)=206000×0.048/(2×25)≈198MPa (Δ = interference, r = inner ring radius). The inner ring cross-section area of the 61810 is A=π×(R²-r²)=π×(28.75²-25²)=π×(826.6-625)=π×201.6≈633mm². The 198MPa stress is very small compared with the tensile strength of the bearing steel (GCr15, about 2000MPa) and should not cause cracking. The real cause of the cracking is that no guide sleeve was used during pressing, so the bearing skewed on the shaft (about 0.5° off axis). The resulting local stress concentration produced an axial bending stress in the inner ring which, superimposed on the circumferential stress, exceeded the strength of the material. The crack started at the oil groove or marking where the stress was concentrated and propagated through the whole inner ring.

Correct Solution

1) Use a looser interference for thin section bearings (k6, maximum interference 0.018mm);
2) Use a tapered guide sleeve when mounting (to ensure the bearing enters smoothly without skew);
3) Thin section bearings are recommended for heated mounting (oil bath 80~100℃, hot mounting reduces the interference stress);
4) After installation, check that the bearing rotates freely (it should turn smoothly by hand);
5) After installation, carry out a magnetic particle inspection (to confirm that there are no cracks).

Checklist

References

FT_23_Bearing Selection Standards

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL