MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Selection Error Cases › Deformation of a Thin-Wall
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Deformation of a Thin-Walled Bearing Housing Distorts the Outer Ring (Thin-Walled Housing)

E41-552 · Bearing Selection · Thin-Walled Housing Deformation Distorting the Bearing Outer Ring · ★★★★

Problem Symptom

A thin-walled bearing housing (an aluminium housing with a 5mm wall) deformed when the bolts were tightened, and the roundness of the bearing outer ring degraded from 0.002mm to 0.015mm.

Root Cause

The bearing housing is aluminium (6061-T6) with a 5mm wall, fixed to the base with four M8 bolts. At a bolt torque of 20Nm the preload is about 12kN, producing a compressive stress in the thin aluminium wall of σ_c=F/A=12000/(π×0.02×0.005)≈38MPa (washer OD Φ20mm, wall thickness 5mm). 38MPa is below the yield strength of aluminium (276MPa), but the compressive deformation through the wall is δ=σ×h/E=38×5/68900≈0.003mm (aluminium E=68900MPa), a very small deformation. However, because the bolts were tightened in the wrong order (not diagonally), the aluminium wall bent (the metal around the bolt holes rose by about 0.005mm) and the roundness of the housing bore (Φ62H7) degraded from 0.002mm to 0.015mm. The bearing outer ring then took on the corresponding oval distortion in the oval bore, and the radial clearance changed from 0.005~0.020mm (C0 group) to 0.005~0.045mm (uneven clearance). The clearance then varied four times per revolution of the bearing (about half a revolution of each rolling element), producing periodic impacts.

Correct Solution

1) Minimum wall thickness of the bearing housing ≥10mm (to increase stiffness and reduce deformation);
2) Bolt tightening sequence: diagonal in three stages (50% → 75% → 100%);
3) Bore machining accuracy: roundness at IT6 or better (Φ62 → 0.019mm), so that wall deformation stays within the permitted range;
4) Reduce the bolt torque to 70% of the standard value (12kN → 8.4kN) to reduce deformation;
5) Alternatively use a steel housing of greater wall thickness (E=206GPa, deformation only one third of that of aluminium).

Checklist

References

FT_23_Bearing Selection Standards

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL