E41-556 · Bearing Selection · Progressive Bearing Electrical Erosion from Static Discharge · ★★★★
Light electrical erosion was detected on a fan bearing (shaft voltage about 1V) but no earthing carbon brush was fitted in time. Three months later the erosion had worsened and severe discharge pits had appeared on the raceway.
The fan generates a shaft voltage of about 1V during operation (static electricity from friction between the impeller and the air), while the breakdown voltage of the bearing oil film is about 0.5V, so the 1V > 0.5V and the oil film breaks down, producing discharge. Initially the discharge current is about 1mA with an energy of about 1mJ per discharge, forming minute discharge pits on the raceway surface (diameter about 1μm, depth about 0.5μm). After three months (about 10⁷ discharges) the raceway surface is covered with discharge pits (like a grit-blasted surface) and the roughness degrades from Ra0.2μm to Ra3.0μm. On such a rough surface a stable oil film can no longer form (film thickness about 0.5μm against a peak-to-valley roughness of 3μm), metal-to-metal contact increases, the friction coefficient rises from 0.004 to 0.02 and heat generation increases five-fold. The bearing temperature rises from 45℃ to 80℃, the grease carbonises and the raceway wears further. At the same time the discharge current grows to 10mA, the erosion pits deepen to 3μm and the cage and rollers are also affected by the erosion.
1) A grounding carbon brush must be fitted whenever the shaft voltage (static) exceeds 0.5V (reducing the shaft voltage to ≤0.1V);
2) In the early stage of electrical erosion (raceway roughness Ra≤0.8μm) the bearing can be cleaned and put back into service with a grounding carbon brush fitted;
3) In the intermediate stage (Ra≤1.6μm) the grease must be renewed and a grounding carbon brush fitted;
4) Severe erosion (Ra>3μm or pit depth >2μm) requires bearing replacement;
5) Fit a static eliminator at the fan inlet (reducing static generation).
FT_23_Bearing Selection Standards