E41-577 · Bearing Selection · Centrifugal Fan Rotor Bearing Overload · ★★★
After eight months of running the bearing (6310) of a fan developed abnormal noise and vibration. On disassembly extensive spalling was found on the inner ring raceway. The measured vibration rose from 2mm/s to 18mm/s.
The fan rotor has a mass m=120kg and runs at n=2950r/min, and the belt drive generates an additional radial force. The radial load on the bearing is F_r=mg+F_belt=120×9.8+1500=2676N. The 6310 bearing has a dynamic load rating C=61.8kN, so the load ratio P/C=2676/61800=0.043 (4.3%) and P=0.043C, giving L10=(C/P)³=(1/0.043)³≈12573 million revolutions. At 2950r/min the life is L10h=12573×10⁶/(60×2950)≈71000h≈8 years. In fact it failed after only eight months. Inspection showed a coaxiality deviation of 0.08mm in the bearing housing bore, so the inner and outer rings were tilted relative to each other at installation and the actual load distribution was uneven, the maximum rolling element load being 2.3 times the average. The equivalent dynamic load is P_eq=2.3×2676=6155N, P_eq/C=0.1, L10=(1/0.1)³=1000 million revolutions, and the life is L10h=1000×10⁶/(60×2950)≈5650h≈8 months, which matches the actual failure.
1) Coaxiality requirement for the housing bore ≤0.03mm (precision grade ≤0.01mm);
2) After installation, measure the rotation torque of the bearing (it should be uniform with no jamming);
3) The equivalent dynamic load should be kept below 5~8% of the dynamic load rating of the bearing;
4) Select self-aligning ball bearings (able to compensate coaxiality deviations of 0.5°~2°);
5) Or change to housed bearings (the UCP series, which can compensate installation errors).
FT_Bearing Design Handbook