E41-581 · Bearing Selection · Mill Roll Neck Bearing Cage Fracture · ★★★★
The taper roller bearing (32226) on the roll neck of a rolling mill developed violent vibration and noise after only two hours of running. On disassembly the cage was fractured in many places and the rollers had spilled out.
When installing the 32226 taper roller bearing, in order to eliminate the axial clearance the operator over-tightened the lock nut (specified torque 1200Nm, tightened to about 2000Nm). The excessive preload changed the axial clearance of the bearing from the standard 0.04~0.08mm to -0.03mm (negative clearance). Under negative clearance the contact pressure between the large end faces of the rollers and the inner ring flange rises sharply. The normal contact stress is about 200MPa; with negative clearance it rises to about 800MPa (beyond the limit). The sliding friction coefficient between the roller end face and the flange is about 0.08, so the friction heat is P=μ×F×v=0.08×8000×1.5≈960W (normally about 120W). After two hours the cage temperature exceeded the flash point of the lubricant, the oil carbonised and the cage (brass) deformed under the combination of high temperature and heavy load → fracture → the rollers spilled out.
1) Taper roller bearings must be locked to the torque specified by the manufacturer;
2) After locking, measure the axial clearance (with a dial indicator, it should be within 0.04~0.08mm);
3) Use hydraulic nuts for large bearings (torque error ≤±5%);
4) After installation, turn the bearing by hand (it should be uniform with no jamming);
5) Check the temperature rise after a 30min trial run (should be ≤ambient temperature +40℃).
FT_Bearing Design Handbook