Electrical Erosion of the Bearing Caused by Inverter Current Breaking Down the Lubricating Film (Inverter-Fed Motor Bearing)

E41-595 · Bearing Selection · Inverter-Fed Motor Bearing (45kW) · ★★★★

Problem Symptom

After six months of running an inverter-fed motor (45kW, vector control) developed bearing vibration and abnormal noise. On disassembly the raceway surface was covered with dense discharge erosion pits.

Root Cause

In an inverter-fed motor the high du/dt of the PWM pulses (about 5000V/μs) is coupled to the rotor through the distributed capacitance of the motor windings, producing a shaft voltage on the rotor (about 10~30V). When the shaft voltage exceeds the breakdown voltage of the bearing oil film (film thickness about 0.2μm, dielectric strength about 15V/μm, breakdown voltage about 3V), spark discharge (EDM) occurs, with a discharge current density as high as 10⁶A/mm² and an instantaneous temperature of 10000℃ that melts the raceway surface into craters (diameter about 10~50μm). Each crater is about 5μm deep, and after six months the raceway surface coverage reaches 30%, with the rolling elements impacting over the erosion pits. The bearing life falls from the design L10h=50000h to about 3000h (a 94% reduction).

Correct Solution

1) Inverter-fed motors must have shaft current protection;
2) Option A: use insulated bearings on the drive end (outer or inner ring coated with ceramic, breakdown voltage ≥1000V);
3) Option B: fit a grounding carbon brush (conducting the shaft voltage to earth, brush contact speed ≥15m/s);
4) Option C: fit a shaft grounding ring (conductive fibre, maintenance free, grounding resistance ≤0.5Ω);
5) Option D: fit a common mode filter at the output (suppressing the common mode voltage that generates the shaft voltage).

Checklist

References

FT_Bearing Design Handbook