Oil Level Too Low in the Bearing Housing Causes Bearing Burnout (Large Gearbox)

E41-596 · Bearing Selection · Large Gearbox Bearing · ★★★★

Problem Symptom

Three months after start-up the high-speed shaft bearing of a large gearbox (200kW) ran continuously at 95℃. On shutdown the oil level in the housing sump was found to be inadequate (only 30% remaining).

Root Cause

The high-speed shaft bearings of the gearbox use oil bath lubrication (the oil level is centerd on the lowest rolling element center) with about 1.5L of lubricant. During operation the shaft end seal (skeleton oil seal) wore and lubricant leaked slowly from the output shaft end (about 0.5L per month). Over three months 1.5L leaked away and the oil level fell from the lowest rolling element center to below the rolling elements (about 70% of the oil lost). With the oil level too low the bearings are lubricated only by splash (no oil ring) and lubrication is inadequate. In the starved state: (1) the friction coefficient of the bearing rises from 0.004 to 0.02 (five times higher) and friction heat rises five-fold; (2) the bearing temperature rises from 45℃ to 95℃; (3) the lubricant oxidises rapidly at the high temperature (the oxidation rate doubles for every 10℃ rise), the acid number rising from 0.5mgKOH/g to 2.0mgKOH/g (out of limits); (4) the degraded lubricant can no longer form an effective oil film → metal-to-metal contact → intensified wear → further temperature rise → a vicious circle → bearing burnout.

Correct Solution

1) An oil bath lubricated bearing housing must have a sight glass (transparent window) with an oil level mark;
2) Check the oil level every shift (it should be 2~5mm above the center of the lowest rolling element);
3) Inspect the seal condition at regular intervals (monthly, replace promptly if oil is leaking);
4) Fit an oil level switch (automatic alarm or shutdown on low oil level);
5) For long-term unattended equipment use circulating oil lubrication (ample oil volume, automatic replenishment).

Checklist