Excessive Interference Between the Bearing Inner Ring and the Shaft Cracks the Inner Ring (Tight Fit Installation)

E41-597 · Bearing Selection · High-Power Motor Bearing Installation · ★★★★

Problem Symptom

When installing a bearing (NU322 cylindrical roller bearing) on a large motor (160kW) the inner ring was pressed in hydraulically. After 24h an axial crack (about 30mm long) appeared in the bearing inner ring.

Root Cause

The bore of the NU322 bearing is Φ110mm and the fit on the shaft was a P6 interference fit (interference 0.022~0.058mm, mean 0.04mm). During installation the operator pressed it straight in hydraulically (without heating the bearing), so the inner ring was subjected to a huge hoop tensile stress. The pressing force is F=π×d×L×μ×p (d=110mm, L=bearing width 63mm, μ=steel-steel friction coefficient 0.15, p=contact pressure≈σ×δ/d=206000×0.04/110≈75MPa), F=3.14×0.11×0.063×0.15×75000000≈245kN. The hoop tensile stress produced as the inner ring is pressed in is σ_t=δ×E/d=0.04×206000/110≈75MPa. The tensile strength of GCr15 is about 1600MPa, so 75MPa is less than 5% and appears safe. In reality the bearing inner ring retains residual austenite after heat treatment (about 8~12%), and under the pressing stress combined with the alternating load in service the residual austenite transforms to martensite (about 4% volume expansion), producing transformation stress. The transformation stress superimposed on the assembly stress exceeds the fracture toughness of the material at the critical sections (the root of the oil groove, the edge of the keyway and other stress concentration sites), producing a crack. The crack started at the root of the oil groove in the inner ring end face and propagated about 30mm circumferentially before stopping (stress relief).

Correct Solution

1) Bearings with a large interference must be installed heated (oil bath or induction heating, 100~110℃);
2) It is strictly prohibited to press a large-interference bearing straight on cold with hydraulics (especially interference above P6);
3) Precautions for heated installation: heating temperature ≤120℃ (to avoid tempering the bearing steel), inner ring expansion δ=α×d×ΔT=12×10⁻⁶×110×100=0.132mm;
4) After installation, check the inner ring for cracks (dye penetrant inspection);
5) Special materials (ceramic bearings) must never be heated and require a shrink fit (the shaft is cooled).

Checklist

References

FT_Bearing Design Handbook

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL