E41-603 · Bearing Selection · Continuous Production Line Bearing (24h operation) · ★★★
Eight months after start-up the transmission bearing (6309) of a continuous production line, which was being topped up with grease every three months as recommended by the manufacturer, was found on disassembly to contain old grease that had carbonised and turned black, and the new grease could not penetrate.
The 6309 bearing runs continuously 24h a day (speed 1800r/min) with a working temperature of about 70℃. A lithium grease is used (applicable temperature -20~120℃), so theoretically 70℃ is acceptable. The base oil evaporation rate of the grease at 70℃ is about 1% per month, so after three months the base oil loss is about 3% and the consistency changes little. However, during continuous operation the bearing seals (2RS) trap the grease inside the cavity, and when fresh grease is added the old grease cannot escape (there is no grease relief port). After eight months two top-ups of fresh grease had been added (about 10g in total) while the bearing cavity holds about 15g, so after mixing the total quantity is excessive. The fresh grease cannot reach the working raceway surface (it is blocked by the old grease) and the bearing is effectively running on the remains of the old grease. The old grease oxidises continuously at 70℃ and after eight months it is fully carbonised (about 8% base oil loss, soap base breakdown), forming a hard crusty residue with no lubricating capability. The bearing runs in a mixture of carbonised old grease and excess fresh grease, the temperature rises to 85℃, accelerating carbonisation and creating a vicious circle.
1) Sealed bearings must have a grease relief port so that the old grease is expelled during periodic relubrication;
2) Top-up interval: for continuously running equipment, grease every 1~2 months (depending on temperature and speed);
3) Amount per top-up: 10~15% of the cavity volume (about 1.5~2.5g);
4) After greasing, run at light load for 30min so that the excess old grease is expelled;
5) Strip, clean and change the grease at regular intervals (a thorough wash and fresh grease every 6 months).
FT_Bearing Design Handbook