Damaged Threads on the Bearing Lock Nut Cause Loss of Axial Locating (Vibrating Equipment)

E41-608 · Bearing Selection · Vibrating Equipment Bearing Axial Locating · ★★★

Problem Symptom

The bearing lock nut (M30×1.5) at the end of a shaft could not be tightened after removal and refitting; the threads stripped and the bearing could not be located axially, with the shaft assembly wandering 0.1mm.

Root Cause

The thread of the lock nut (M30×1.5 fine thread) was tightened to 150Nm at first installation, and the shaft end thread (45 steel, quenched and tempered, strength class 8.8) has a surface hardness of HRC28. The threads of the lock nut (45 steel, hardness HRC22) were damaged during the first removal because of corrosion (no rust preventive oil was applied at installation). At refitting the maintenance worker did not inspect the thread condition and tightened with a pneumatic wrench (impact torque about 300Nm, twice the specified 150Nm), so the damaged threads stripped completely under the excessive torque (shear failure of the thread flanks). The shear strength of the thread is τ=0.5×σ_b=0.5×800=400MPa and the shear area of the M30 thread is A=π×d×L=3.14×0.027×0.015=0.00127m² (L being the contact length of about 15mm for a 1.5mm pitch), giving a maximum shear force F_max=τ×A=400×10⁶×0.00127≈508kN. The axial force corresponding to 300Nm is F=T/(0.2×d)=300/(0.2×0.027)≈55.6kN, far below 508kN. The actual cause of the stripping is that the threads were severely corroded (the effective engagement length fell from 15mm to about 5mm) and, combined with the damage from removal, the remaining effective shear area was only 30% of the original (F_max≈152kN), still above 55kN. The stripping occurred at the transition between thread flanks over four teeth (a stress concentration) and was not a bulk shear failure but a chain reaction following plastic deformation of the first thread.

Correct Solution

1) The thread condition must be inspected after removing the lock nut (visual check plus thread gauge);
2) Apply a rust preventive lubricant to the threads before installation (MoS₂ or a copper-based anti-seize compound);
3) Tightening must be done with a torque wrench (pneumatic wrenches are prohibited);
4) If the thread is stripped, replace the shaft end or repair it with a thread insert (Helicoil);
5) For critical threaded connections: fit a new lock nut every 3 removals.

Checklist

References

FT_Bearing Design Handbook