E41-029 · Reducer/Coupling Selection · Heavy-Duty Mixer · ★★★★
At the moment the mixer started, the reducer output shaft broke clean off at its root; the fracture surface was a 45° helical shape (a typical torsion fracture). The mixing impeller was jammed by material while the motor kept energizing and delivering torque, so the impact torque concentrated on the reducer output shaft.
The reducer rated output torque T_n=5000 Nm; the actual steady-state mixing torque T_steady=3200 Nm. The torque margin under normal operation T_n/T_steady=1.56 (seemingly sufficient, but the starting condition was ignored). When starting, the mixer must overcome the static friction and inertia of the material; the measured peak torque reached 12500 Nm, 2.5 times the rated value. During selection, the SA (start-up factor) for mixer duty was not applied and the KA (application factor) was not multiplied. Per standard JB/T 8853-2015, reducer selection for a mixer should be: T_required=T_steady×KA×SA, with KA=1.75 (moderate shock) and SA=2.0 (start-up), giving T_req=3200×1.75×2.0=11200 Nm; the reducer rated torque should be ≥11200×1.2 (safety factor)=13440 Nm. In fact only 5000 Nm was selected—only 1/2.7 of the requirement.
① Selection formula: T_required = T_steady × KA × SA × 1.2 (safety factor)
② KA (application factor): 1.75 for moderate shock in mixers, 2.0 for heavy shock
③ SA (start-up factor): 2.0 for direct start, 1.5 for soft start, 1.2 for VFD start
④ This example: T_req=3200×1.75×2.0×1.2=13440 Nm
⑤ Selection: choose a reducer with rated torque ≥14000 Nm, e.g. SEW R167 (T_n=15000 Nm)
⑥ Motor side: the coupling torque capacity must also be verified simultaneously
FT_13_Reducer-Motor Matching Selection