E41-030 · Reducer/Coupling Selection · Automated Warehouse Stacker Hoist · ★★★
The hoist motor frequently tripped on overload; measured motor current stayed 25~30% above rated, temperature rise reached 85 K (allowable 60 K). The thermal protection tripped repeatedly, and each fault recovery required 20 min of cooling.
The reducer reduction ratio was selected as i=30:1, motor rated torque T_n=4.5 Nm, load lifting torque required T_load=120 Nm (including heavy material 500 kg and hoist friction). The required motor-end output torque T_motor=T_load/(i×η)=120/(30×0.85)=4.7 Nm, already exceeding the rated torque 4.5 Nm (104%), so overload is inevitable in long-term operation. More seriously, when lifting a heavier load (full 600 kg) T_motor=5.6 Nm (124%), exceeding the thermal-protection threshold. The motor operates in the high-load, low-efficiency region of its constant-torque range; efficiency drops from 85% to 65%, and the extra losses worsen the temperature rise.
① Correct reduction-ratio calculation: i = T_load / (T_n × η) × safety factor
② T_n=4.5 Nm, T_load=120 Nm, η=0.85, safety factor 1.2
③ i=120/(4.5×0.85×1.2)=120/4.59≈26.1, take 25:1 (but output speed must be verified)
④ Actually 30:1 was chosen but the motor overloaded; verification shows i should be ≥46:1
⑤ i=50:1 → T_motor=120/(50×0.85)=2.82 Nm (63% of rated, ample margin ✓)
⑥ Output-speed verification: n_out=1500/50=30 rpm, meets the hoist-speed requirement
⑦ Match a VFD: set the overload-protection curve to match the motor thermal characteristic
FT_13_Reducer-Motor Matching Selection