After 1 h of operation the horizontal reducer sprays oil at the breather cap, with heavy oil stains on the casing. Inspection finds the oil filled ~20 mm above the upper oil-level-gauge mark.
When filling, the oil-level gauge (mid position) was ignored; the operator filled ~20 mm above the full mark (~30% overfill). In operation the gears splash the oil; the high level increases splash volume 5×. Internal casing pressure rises from normal 0.01 MPa to ~0.05 MPa (oil mist + air expansion); the breather cap's venting capacity cannot release the pressure, so oil sprays out. Spray rate ~50 ml/h; after 2 h the level drops to normal and spraying stops. But environmental contamination and oil waste already occurred.
① Reducer oil level: mid position of the gauge (static level at 1/2~2/3 of gauge)\n② Add oil while observing the gauge (avoid overfill)\n③ If overfilled, drain excess from the drain plug\n④ Keep the breather cap clear (check monthly)\n⑤ Large reducers fitted with a breather (desiccant + filter inside)