E41-239 · Reducer Coupling Selection · Heavy-Duty Mixer Reducer Output Shaft · ★★★★
The mixer reducer output shaft fractured at the keyway root, showing a 45° torsional break at the keyway; the coupling-to-shaft key connection shows clear fatigue striations.
Output shaft diameter Φ80 mm, keyway size 22×14 mm (type-A flat key), keyway-bottom fillet radius R = 0.3 mm (standard requires ≥0.5 mm). The small fillet gives stress-concentration factor Kt ≈ 3.2 (from theoretical stress-concentration table). Transmitted torque T = 5000 Nm; nominal torsional stress at keyway τ_nom = T×r/J = 5000×0.04/(π×0.04³/16) = 5000×0.04/0.0001 ≈ 2 MPa. Actual peak stress τ_peak = Kt×τ_nom = 3.2×2 = 6.4 MPa — not high. But the mixer start-up impact torque T_peak = 3×T_nom = 15000 Nm (motor starting-current multiple), and τ_peak_impact = 3.2×6.4 = 20.5 MPa. 45-steel fatigue limit τ-1 ≈ 160 MPa, with 5× safety factor it should not fatigue-fracture. However, keyway machining caused surface burn (grinding cracks); crack depth ~0.1 mm became a fatigue source and grew to fracture after ~10⁵ cycles.
① Keyway-bottom fillet radius R ≥ 0.5 mm (reduce stress concentration)\n② Keyway surface roughness Ra ≤ 1.6 μm, no machining burn\n③ After keyway machining, use magnetic-particle inspection for cracks\n④ Heavy-load shafts use spline connection (far less stress concentration than keyway)\n⑤ Or use an interference-fit coupling (keyless connection)
FT_13_Reducer-Motor Matching Selection