E41-255 · Reducer Coupling Selection · Heavy-Start Fluid Coupling · ★★★★
On a belt conveyor, the fluid coupling (YOX500) melts its fusible plug and sprays oil at full-load start-up; after stopping, the plug must be replaced and oil replenished.
At full-load start-up the fluid coupling has large slip (s = 0.5~1.0); slip power P_sl = P×s = 200×0.5 = 100 kW, all turned into heat. Oil temperature rise rate dT/dt = P_sl/(m×c) = 100000/(15×1800) ≈ 3.7 ℃/s (oil mass m = 15 kg, specific heat c = 1800 J/kg·℃). Full-load start-up takes ~10 s, ΔT = 3.7×10 = 37 ℃. Initial 40 ℃ + 37 ℃ = 77 ℃, far below the fusible-plug melt temperature (140 ℃). But when the conveyor starts under overload (+20% rated load), start time extends to 20 s; combined with accumulated heat from prior start attempts (40 ℃ → 77 ℃ → start fail → residual 55 ℃ → restart → 92 ℃), repeated accumulation drives oil to 140 ℃ and melts the plug.
① Fluid-coupling selection: capacity factor λ should match the actual start-up load\n② For frequent overload starts add auxiliary cooling (oil cooler or air cooling)\n③ Extend start interval (≥5 min between starts for full heat dissipation)\n④ Check whether the conveyor is overloaded (normal load should be below rated)\n⑤ Or use a torque-limiting fluid coupling (smaller start slip, less heat)