E41-397 · Reducer Coupling Selection · Large Gear Reducer Oil-Pump Failure · ★★★★
The forced-lubrication pump of a large gear reducer (500 kW) fails and stops during operation; the reducer keeps running ~10 min unlubricated and the gear flanks severely scuff.
The reducer uses a forced-lubrication system (lube pump + filter + cooler); after pump failure oil cannot reach the gear-mesh zone. Running 10 min unlubricated, flank temperature jumps from 60 ℃ to ~250 ℃ (friction heat Q = μ×F×v = 0.2×50000×10 = 100 kW, flank flash temp ~200 ℃). At high temperature the flanks scuff; tip and root material transfers; flank roughness worsens from Ra1.6 μm to Ra12.5 μm. After scuffing the gears cannot mesh normally; vibration increases and ~2 h later a gear fractures. The forced-lubrication system lacked a standby pump and oil-pressure monitoring, and the operator did not notice zero oil pressure in time.
① Forced-lubrication reducers must have a standby lube pump (one duty, one standby, auto-switch)\n② Oil-pressure monitoring: pressure switch alarms at ≤0.1 MPa, trips at ≤0.05 MPa\n③ Lube-oil flow monitoring: flow switch checks line continuity\n④ Reducer control logic: no pressure built → cannot start; pressure lost → stop immediately\n⑤ Test the standby pump weekly (verify auto-switch function)
FT_13_Reducer-Motor Matching Selection