E41-567 · Gearbox & Coupling Selection · Gear Coupling Tooth Flank Wear · ★★★★
A jaw coupling connecting the motor to the gearbox (frequent starting, 20 times per hour) wore on the tooth flanks, so the backlash increased from 0.2mm to 0.8mm within six months.
The jaw coupling between the motor and the gearbox (module 3mm, 30 teeth) transmits a rated torque T_nom=2000Nm, while the starting impact is T_peak=2×T_nom=4000Nm (direct on-line motor starting). The tooth flank contact stress σ_H=189.8×√(T_peak×K/(d×b×(z/2)))×...≈400MPa. 400MPa is within the allowable range for a gear coupling (about 500MPa), but frequent starting (20 times per hour, 480 per day, about 86400 over six months) subjects the flanks to impact loading (the instantaneous flank stress at each start is about 800MPa). At 800MPa of impact stress the flanks develop micro-pitting (depth about 0.01mm), the micro-pitting accelerates wear and after six months the flank wear depth is about 0.2mm, with the backlash growing from the standard 0.2mm to 0.8mm. The coupling then impacts across the 0.6mm backlash at every start and stop, producing noise (75dB → 90dB) and vibration (3mm/s → 8mm/s).
1) The flank hardness of a gear coupling in frequent starting duty must be ≥HRC58 (carburised and quenched, wear resistant);
2) Select one size larger coupling (reducing the flank contact stress);
3) Use a flexible coupling (the elastomer absorbs the shock and protects the flanks);
4) Use a soft start on the motor (starting current reduced from 6 times to 2 times, impact torque reduced by 70%);
5) Apply a molybdenum disulphide anti-wear grease to the flanks at regular intervals (reducing friction and wear).
FT_13_Gearbox and Motor Matching Selection