E41-568 · Gearbox & Coupling Selection · Loose Gearbox Foundation Bolts · ★★★
Three months after start-up the torque of the M24 foundation bolts of a gearbox base had fallen from the standard 800Nm to 400Nm and the horizontal vibration of the gearbox housing rose from 5mm/s to 15mm/s.
The four M24 foundation bolts of the gearbox base were initially tightened to 800Nm (grade 8.8 bolts), giving a preload F_pre≈240kN. The unbalance force produced while the gearbox runs is F_unbalance=m×e×ω²=500×0.05×10⁻³×157²≈616N (m=500kg, e=0.05mm eccentricity, ω=157rad/s≈1500r/min). 616N is far below the friction force F_fric=μ×F_pre×n=0.15×240×4=144kN, so in theory it should not loosen. However, the impact torque at starting and stopping (T_peak=3×T_nom=6000Nm with direct on-line motor starting) produces an instantaneous radial force F_radial=T_peak/R=6000/0.2=30000N. This alternating force passes through the base into the foundation bolts, and the bolts suffer fretting wear under the alternating tensile force (about 7500N per bolt). After three months the preload has fallen to 120kN (a 50% reduction) and the friction to 72kN. 72kN is still far above 30000N, so the main cause of the loosening is not the radial force but fretting wear between the base and the foundation, which reduces the bolt elongation and therefore the preload.
1) Tighten the foundation bolts with a torque wrench (M24 at 800Nm, tightened diagonally in three stages);
2) Install an epoxy grout layer between the base and the foundation (filling the gap, raising the contact stiffness and reducing fretting);
3) Fit anti-loosening washers on the bolts (Nord-Lock wedge-locking, vibration resistant);
4) Re-check the bolt torque at regular intervals (monthly, re-tighten when the torque falls below 90% of the standard value);
5) Fit locating keys to the gearbox base (mill a keyway between the base and the foundation and fit a locating key to prevent transverse movement).
FT_13_Gearbox and Motor Matching Selection