Problem Description

The clamp force gradually drops from 2000 kN to 1500 kN, the holding time shortens from 15 s to 5 s, and the product shows flash defects. The hydraulic cylinder leaks internally slowly and the piston seal fails.

Root Cause

An NBR (nitrile rubber) seal (service range -30~80℃) was selected, but the injection molder's hydraulic oil actually runs at 80~90℃ for long periods (continuous high-speed injection, holding, and mold open/close cycles generate large hydraulic heat). NBR used above 80℃ ages faster: plasticizer bleeds out of the nitrile → the rubber hardens → it loses elasticity → compression set grows (about 20% at 70℃×24 h, rising to 60% at 90℃×24 h). The seal can no longer compensate for the clearance between cylinder bore and piston, and high-pressure oil leaks past the sealing face to the low-pressure side.

Corrective Solution

① Seal-material selection principle: the operating temperature must stay at least 20℃ below the seal material's maximum service temperature
② In this case oil temperature is 85℃: select FKM (fluororubber, service -20~200℃ ✓)
③ Recommended: FKM + PTFE composite seal (combined seal), with excellent wear and temperature resistance
④ Also lower the oil temperature: add a plate heat exchanger (cooling-water flow 5 L/min) to keep oil temperature ≤55℃
⑤ Piston-seal structure: change to a double seal (main FKM seal + dust seal) + leak return groove
⑥ Periodically (every 500 h) review the oil-temperature log; if over-limit, immediately inspect the cooling system