Problem Description

During platform descent severe shock and vibration occur and the cargo on the platform tips over. The descent speed is uncontrolled, varying from fast to slow, and the operator must operate carefully to avoid dropping the load.

Root Cause

The lift-platform descent circuit has only a standard directional valve (Y-center function) and no counterbalance valve (speed-limiting / back-pressure valve). Under its own weight the platform descends rapidly, and the lower cylinder chamber goes into vacuum → cavitation → aeration. Because the load direction coincides with the velocity direction (negative load), gravity acceleration makes the speed run away. Without back pressure, even the pilot-operated check valve cannot limit the descent speed. As descent speed grows, the pump cannot supply enough oil to fill the lower chamber; vacuum rises, dissolved air comes out of solution forming cavities, causing noise, vibration, and component cavitation.

Corrective Solution

① Negative-load circuits must have a counterbalance valve (stacked or subplate type)
② Counterbalance-valve setting pressure P_set = (m×g/A_piston + back pressure) × 1.3
③ In this case load m = 2000 kg, A_piston = π×0.08²/4 = 0.005 m²
④ P_set=(2000×9.8/0.005 + 500000)×1.3=(3.92+0.5)×1.3≈5.7MPa
⑤ Counterbalance valve model: Sun CAEALHN (adjustable setting pressure 5~21 MPa)
⑥ Stack a pilot-operated throttle valve to control descent speed (inlet throttling + outlet throttling, bidirectional control)
⑦ Pilot-ratio selection: counterbalance valve pilot ratio 1:3 or 1:5, ensuring it opens even at low pilot pressure

Checklist

Reference

FT_32_Hydraulic System Design

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL