E41-043 · Sensor Electrical Selection · Stamping-Press Displacement Monitoring · ★★★
The stamping-slider stroke-detection signal shows flat-top saturation near bottom dead point, so position accuracy cannot be judged. The system thinks the slider has not arrived and keeps applying pressure, overloading the die.
The draw-wire displacement sensor has a 50 mm range, but the actual stamping stroke is 55 mm (including 5 mm die compression), exceeding the range by 5 mm (10%). After exceeding range, the sensor's internal limiter fixes the output at the voltage for maximum range (10 V), creating a 5 mm dead-band signal. The control system always reads 10 V as the position signal and cannot distinguish the slider's actual position.
① Sensor range-selection principle: range ≥ measurement span × 1.2 (20% margin)
② Actual stroke 55 mm → range should be ≥ 55×1.2 = 66 mm → select 75 mm standard range
③ Draw-wire displacement sensor with 75 mm nominal range (e.g., NOVOSTRICTIVE LWH-0075)
④ Installation adjustment: align sensor zero to top dead point; 75 mm range covers 55 mm stroke with margin
⑤ Electrical config: map sensor 0~10 V output to 0~75 mm; set range upper/lower limits in PLC
FT_33_Sensor Selection Guide