Knowledge Base › Selection Error Cases › Displacement-Sensor Insufficient Range Causing Output Saturation Distortion (Stamping-Press Displacement Monitoring)

Displacement-Sensor Insufficient Range Causing Output Saturation Distortion (Stamping-Press Displacement Monitoring)

E41-043 · Sensor Electrical Selection · Stamping-Press Displacement Monitoring · ★★★

Problem Description

The stamping-slider stroke-detection signal shows flat-top saturation near bottom dead point, so position accuracy cannot be judged. The system thinks the slider has not arrived and keeps applying pressure, overloading the die.

Root Cause

The draw-wire displacement sensor has a 50 mm range, but the actual stamping stroke is 55 mm (including 5 mm die compression), exceeding the range by 5 mm (10%). After exceeding range, the sensor's internal limiter fixes the output at the voltage for maximum range (10 V), creating a 5 mm dead-band signal. The control system always reads 10 V as the position signal and cannot distinguish the slider's actual position.

Corrective Solution

① Sensor range-selection principle: range ≥ measurement span × 1.2 (20% margin)
② Actual stroke 55 mm → range should be ≥ 55×1.2 = 66 mm → select 75 mm standard range
③ Draw-wire displacement sensor with 75 mm nominal range (e.g., NOVOSTRICTIVE LWH-0075)
④ Installation adjustment: align sensor zero to top dead point; 75 mm range covers 55 mm stroke with margin
⑤ Electrical config: map sensor 0~10 V output to 0~75 mm; set range upper/lower limits in PLC

Checklist

Reference

FT_33_Sensor Selection Guide

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL