E41-045 · Sensor Electrical Selection · Lithium-Battery Electrode Coating Thickness Inspection · ★★★★★
Coating thickness control requires ±1 μm, but online measured values fluctuate ±3 μm, preventing effective closed-loop control. Product consistency is poor and yield is only 50%.
A laser displacement sensor (triangulation reflection) was selected with 2 μm resolution and ±1.5 μm repeatability. The total measurement-system error = √(4+2.25+4+1) = √11.25 ≈ 3.35 μm. The tolerance band width = 2 μm × 2 = 4 μm; the 3.35 μm total error already occupies 84% of the band. By the rule that measurement-system error should be ≤ 1/5 of the tolerance band, it should be ≤ 0.8 μm. The actual 3.35 μm exceeds this by 4×.
① Measurement-system accuracy requirement: total error ≤ 1/5 of tolerance band = ±0.4 μm
② Selection: high-precision chromatic confocal displacement sensor (resolution 0.02 μm, repeatability ±0.05 μm)
③ Recommend: Keyence CL-3000 series (range 3 mm, linearity ±0.02% FS = ±0.6 μm)
④ Environmental compensation: constant-temperature control (20±0.2℃) to reduce temperature drift
⑤ Calibration: calibrate every 8 h with a standard thickness gauge block (1 mm ±0.1 μm)
⑥ Signal processing: hardware filter (low-pass 20 Hz) + software averaging filter (10-point average)