E41-048 · Sensor Electrical Selection · Automated Warehouse Storage-Location Detection · ★★
For some storage locations with cargo, the sensor outputs a no-cargo signal, causing the stacker to pick empty and crash into the rack and cargo. The fault appears randomly and is hard to troubleshoot.
A photoelectric reflective sensor is mounted under the rack beam, with emitter and receiver integrated. When cargo is placed slightly forward (protruding 10~20 mm beyond the pallet front edge), the cargo edge blocks the sensor emission path, but the reflective surface is not in the right position, so the sensor misreads it as no cargo. And when the stacker picks, its fork extends into the location and may push the cargo further off, creating a vicious cycle. The sensor is mounted only at one end of the beam; for a 1200 mm-wide location it detects only one point (insufficient coverage) — any slight cargo offset enters the blind zone.
① Installation-position optimization: sensor mounting should cover the entire location width
② Plan A: install a through-beam sensor on each side of the location (emitter and receiver on opposite sides) to ensure the beam crosses the entire location
③ Plan B: use multiple reflective sensors (one every 300 mm) to cover the wide location
④ Sensor type: through-beam is more reliable than reflective (unaffected by cargo color/surface reflectivity)
⑤ Mounting bracket: design an adjustable L-bracket; calibrate each storage location individually after installation
⑥ Given cargo placement deviation, the sensor detection point should avoid the cargo edge zone (50 mm behind the location front edge)
FT_33_Sensor Selection Guide