Knowledge Base › Selection Error Cases › Magnetic-Scale Head Contamination Causing Position-Signal Loss (CNC Machine Tool)

Magnetic-Scale Head Contamination Causing Position-Signal Loss (CNC Machine Tool)

E41-278 · Sensor Electrical Selection · CNC Machine-Tool Magnetic-Scale Contamination · ★★★★

Problem Description

After one year of use, the CNC machine tool's magnetic scale frequently alarms with position loss; the X-axis homing deviation reaches 0.1 mm. Cleaning the magnetic scale restores normal operation.

Root Cause

The magnetic scale (accuracy ±5 μm/m) reads magnetized-scale signals via a magnetic head. The machine cutting fluid (water-based emulsion) contains iron chips and grinding particles (1~10 μm). The iron chips are attracted by the magnetic scale's field and adhere to its surface. After about one year a 0.1 mm-thick layer of iron chips plus cutting fluid builds up on the scale surface. The head-to-scale gap increases from the initial 0.3 mm to 0.5 mm (raised by the debris), and the magnetic signal strength read by the head attenuates by about 60% (magnetic field strength is inversely proportional to the gap squared). The signal strength falls below the head's minimum trigger threshold and position data is lost. After power-off and restart the machine may recover, but the home reference has been corrupted by contamination, giving a 0.1 mm homing deviation.

Corrective Solution

① The magnetic scale must have a protective cover (stainless-steel hinged type, IP67)\n② Add an air seal at the head (positive-pressure compressed-air purge, 0.05 MPa)\n③ Redirect the cutting fluid (away from the magnetic-scale mounting)\n④ Clean the magnetic-scale surface regularly (monthly, with non-woven cloth and alcohol)\n⑤ Or switch to an optical scale (immune to iron-chip attraction)

Checklist

Reference

FT_33_Sensor Selection Guide

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »