Problem Description

The injection-molding machine barrel temperature control fluctuates greatly (set 200℃, actual 180~220℃), and the products show shrinkage and flash defects.

Root Cause

The temperature sensor is a thermocouple (Type K, probe diameter Φ6 mm) mounted in the barrel heating bore (bore depth 50 mm, bore diameter Φ6.5 mm); the gap between the probe and bore wall is about 0.25 mm, filled with air (thermal conductivity 0.026 W/mK). The thermal resistance R = ln(r2/r1)/(2π×L×K) = ln(3.25/3)/(2π×0.05×0.026) ≈ 12 K/W. The sensor time constant τ = R×C = 12×0.1 = 1.2 s (C is the probe heat capacity, about 0.1 J/K). But the barrel heater power is 3 kW, and the heating rate dT/dt = P/(m×c) = 3000/(10×500) = 0.6℃/s; heating from 200℃ to 220℃ takes 33 s, far longer than the sensor τ of 1.2 s, so the response should be adequate. The actual temperature-control lag comes from: the sensor is mounted 100 mm from the heater, and the barrel conduction delay is about 10 s. The PID controller produces overshoot in such a lagging system.

Corrective Solution

① Temperature-sensor mounting requirement: fill the gap between probe and bore wall with thermal grease (thermal conductivity 2 W/mK, reducing thermal resistance 80×)\n② Sensor probe specification: Φ3 mm (thin probe, faster response)\n③ Use a Pt100 platinum RTD (faster response than a thermocouple)\n④ Auto-tune the temperature controller PID parameters (optimize automatically based on system lag)\n⑤ Mount the sensor close to the heating zone (to reduce conduction delay)