Knowledge Base › Selection Error Cases › Encoder-Cable Damage Causing Signal Interruption (Cable-Chain Moving Cable)

Encoder cable damaged causing signal interruption (drag-chain motion cable)

E41-280 · Sensor Electrical Selection · Drag-chain Encoder Cable · ★★★

Problem Description

After running 3 months in the cable chain, the robot seventh-axis encoder cable loses signal; inspection finds the cable jacket cracked at the chain bending point and the conductor broken.

Root Cause

The encoder cable (outer diameter Φ8mm) runs in a drag chain with bending radius R=100mm, chain speed 1m/s, acceleration 5m/s². The bend-radius ratio (bend radius / cable OD) = 100/8 = 12.5 (recommended ≥15). The cable undergoes reciprocating bending fatigue in the chain, bending once per second (3×10⁶ cycles/year). The PVC jacket (rated for about 2 million bends) develops fatigue cracks after about 2.7 million bends, and the shield and conductors break. When the encoder signal is lost, the servo system alarms for excessive position deviation.

Corrective Solution

① Drag-chain cable selection: high-flex cable (bend life ≥10 million cycles)\n② Choose smaller cable OD (Φ6mm, bend-radius ratio ≥15)\n③ Drag-chain bend radius R ≥10×D (D = cable OD)\n④ Anchor cable in drag chain (leave slack at both ends to reduce tension)\n⑤ Servo auto emergency stop on encoder signal loss (collision prevention)

Checklist

Reference