E41-289 · Sensor Electrical Selection · Long-Distance Conveying Rotary-Encoder Positioning · ★★★★

Problem Description

The conveyor positioning system (rotary encoder + PLC high-speed counter) accumulated a 50mm positioning deviation over 3 months; 3 of 100 positioning operations exceeded tolerance.

Root Cause

A rotary encoder (incremental, 1000P/R) connects to the drive roller (diameter 200mm) via a flexible coupling. The displacement per pulse is Δs = π×D/N = 3.14×200/1000 = 0.628mm/pulse. The high-speed counter's max counting frequency is 50kHz; at the encoder's top speed 2m/s the pulse frequency f = v/Δs = 2000/0.628 ≈ 3185Hz, far below 50kHz. But the PLC high-speed counter's input filter time is set to 5ms (default), larger than the encoder pulse period 1/3185 ≈ 0.314ms, so some pulses are filtered out (dropout). The dropout rate is about 3% — 3 of every 100 pulses lost — and accumulated positioning error = total displacement × 0.03. Over 3 months the accumulated travel is ~30km (300m/day × 300 days), about 4.8×10⁷ total pulses, ~1.44 million lost, positioning deviation 1.44M×0.628mm ≈ 904m; but the system periodically returns to zero, so the actual accumulated deviation is the drift before each zeroing (about 50mm).

Corrective Solution

① High-speed counter input filter time should be ≤ half the encoder pulse period\n② This example: pulse period 0.314ms, filter time should be ≤0.157ms\n③ Choose lower encoder pulse count: 1000→500P/R (period 0.628ms, easier to match)\n④ Or use an absolute encoder (no accumulated error, no zero return needed)\n⑤ Conveyor periodically auto-returns to zero (once per 100m, eliminating accumulated error)

Checklist

Reference