E41-290 · Sensor Electrical Selection · Equipment-Vibration-Monitoring Sensor Mounting · ★★★★

Problem Description

The vibration monitoring system's acceleration sensor on the fan bearing housing reads abnormally high (up to 50m/s²), while a handheld vibrometer at the same location reads only 5m/s².

Root Cause

The acceleration sensor is fixed to the bearing housing with an M5 bolt; there is about 0.5mm gap between the sensor base and mounting surface (uneven surface), filled with a silicone spacer (thickness 0.5mm, Shore A30). The silicone spacer stiffness is about 100N/mm; with the sensor mass (20g) it forms a spring-mass system with natural frequency fn = 1/(2π)×√(K/m) = 1/6.28×√(100000/0.02) ≈ 356Hz. The fan's rotation frequency is 25Hz (1500rpm); its 10th harmonic (~250Hz) is close to the sensor-spacer system's natural frequency (356Hz), producing resonance amplification. The amplification factor Q ≈ 1/(2ζ) = 1/0.1 = 10 (silicone spacer damping ratio ζ≈0.05). The fan vibration of 5m/s² is resonance-amplified to 50m/s², and the reading deviates severely from the true value.

Corrective Solution

① Acceleration sensor mounting surface should be flat (flatness ≤0.01mm), direct steel-to-steel contact\n② Elastic spacers (silicone/rubber/nylon) are prohibited for mounting acceleration sensors\n③ Sensor mounting resonant frequency should be ≥3× the upper limit of the measured frequency\n④ Sensor uses stud mounting (M5 thread, tightening torque 3Nm)\n⑤ Or use magnetic-base mounting (frequency response ≤2kHz, convenient for mobile measurement)

Checklist

Reference