Problem Description

The safety-door limit switch (mechanical) failed after 6 months of operation; the PLC always reads an open signal. Inspection found the contact surface oxidized and blackened.

Root Cause

The safety-door limit switch is normally closed during normal operation (door closed, contacts conducting), acting only about 100 times per year (door open/close). The contact material is silver alloy (AgNi), held closed long-term under micro-current (PLC input ~5mA, DC24V). With contacts closed there is no arc-cleaning effect; the contact surface slowly oxidizes/sulfidizes in air (Ag₂S black film), and after about 6 months the contact resistance rises from 5mΩ to about 100Ω. The PLC input module's conduction threshold is about 2mA (corresponding to 12kΩ); 100Ω is still far below 12kΩ, so in principle no misjudgment. But the total resistance of multiple paralleled contacts (multi-door interlock) increases, plus line resistance, lowering the effective signal the PLC detects. In addition, the tiny thermal stress at micro-current thickens the oxide layer, eventually causing contact failure.

Corrective Solution

① Long-closed contacts should use a low-current type (gold contacts, oxidation-resistant)\n② Or use a non-contact safety switch (magnetic-encoding type, no contact-oxidation issue)\n③ Increase PLC input current (from 5mA to 10mA, piercing the oxide film)\n④ Periodic contact test (manually trigger once a month, cleaning contacts via arc)\n⑤ Or parallel a diode across the contact (diode carries small current, contact carries large current)