E41-295 · Sensor Electrical Selection · Platform-Leveling Inclination Sensor · ★★★
The inclination sensor (range ±10°, accuracy 0.01°) outputs -0.08° on a horizontal platform, while the actual platform levelness is 0.01°. The sensor mounting reference is not level.
The inclination sensor is fixed to a bracket with two M4 screws; the bracket is welded to the platform. After welding, the bracket mounting surface has a parallelism deviation of about 0.08° from the platform's horizontal plane (welding deformation). The sensor output contains two parts: actual platform tilt (0.01°) + mounting-surface deviation (-0.09°) = -0.08°. The control system's leveling algorithm uses the sensor output as reference and adjusts the platform to -0.08° (nominally level), but the sensor already indicates zero, so the platform is actually tilted 0.08°. This mounting deviation was not calibrated out after installation, so the platform can never be leveled to true horizontal.
① The parallelism of the inclination sensor mounting reference should be ≤5× sensor accuracy\n② This example: sensor accuracy 0.01°, mounting-surface parallelism should be ≤0.05°\n③ Perform zero calibration after mounting (record the zero offset on a known-level surface)\n④ Software compensation: subtract the zero offset from the sensor output\n⑤ Replace the welded bracket with an adjustable bracket (3-point support, leveling via adjusting screws)