E41-441 · Sensor Electrical Selection · Hall Sensor Air Gap Too Large · ★★★
The Hall sensors of a brushless DC motor frequently lose the commutation signal during operation, and the motor runs with a missing phase. Inspection found that the gap between the Hall element and the magnet had increased from the standard 0.5mm to 1.2mm.
The Hall sensor is mounted inside the motor end cap, with a standard gap (air gap) of 0.5±0.1mm from the rotor magnet. During operation, the end cap undergoes thermal expansion due to temperature rise (about 50℃) (aluminum-alloy end cap, α=23×10⁻⁶/℃); the end cap's axial expansion is ΔL=α×L×ΔT=23×10⁻⁶×20×50=0.023mm. A 0.023mm increase in air gap should not cause signal loss. The actual reason the air gap grew to 1.2mm: after long-term operation the bearings wore (axial clearance increased from 0.05mm to 0.3mm), causing axial play of the rotor. At the same time, the end-cap fastening bolts loosened under vibration (the gap between end cap and housing increased), further enlarging the air gap. At a 1.2mm air gap, the magnetic flux density of the magnet at the Hall element drops from 0.3T to about 0.1T (per magnetic-circuit calculation, a 2.4× air-gap increase lowers B by about 67%). The Hall element's trigger flux density is about 0.15T, and 0.1T<0.15T, so the Hall element cannot trigger reliably.
① Hall sensor mounting air gap: ≤0.5mm (per manufacturer recommendation)\n② Inspect bearings periodically (replace when axial clearance >0.1mm)\n③ Apply thread-locking adhesive to end-cap bolts + check torque periodically\n④ Use a high-sensitivity Hall sensor (trigger threshold 0.05T, insensitive to air gap)\n⑤ Or switch to a magnetic encoder (non-contact, allows air gap 1~2mm)
FT_33_Sensor Selection Guide