E41-446 · Sensor Electrical Selection · Batching-Scale Weighing Sensor Off-Center Loading · ★★★★
The three weighing sensors of the batching scale (range 200kg) have inconsistent zeros at no load (deviation ±0.5kg); after loading, the total weight deviates by 2kg (the specified tolerance should be ≤0.2kg).
When the batching scale was installed, the sensor mounting surfaces were not level (tilted about 2°), so under tilt the sensor's force direction was not aligned with its axis. At tilt angle θ=2°, the axial component the sensor carries is F_axial=F×cosθ=400×0.9994≈399.76N (static load 400N), and the lateral component is F_lat=F×sinθ=400×0.0349≈14N. The strain gauges are bonded to the elastomer along the axial direction, and the lateral force produces a certain cross sensitivity in the measurement, about 5%. A 4kg lateral force×5%=0.2kg error, which does not match the 2kg deviation. Furthermore, the three sensors' mounting surfaces have inconsistent levelness (deviation ±2°), so each sensor's lateral force direction and magnitude differ, giving zero differences of ±0.5kg. Also, after the load is placed on the platform, the load center is offset from the platform center by about 50mm, so the load is distributed unevenly among the sensors, with a 2kg difference.
① Weighing sensor mounting-surface levelness ≤0.5° (checked with a spirit level)\n② Use self-aligning bases on the sensor mounting surfaces (automatic leveling, eliminating mounting-angle deviation)\n③ Load-center to platform-center offset ≤10mm\n④ Perform zero calibration and off-center-load correction after sensor installation\n⑤ Use an off-center-load-resistant weighing sensor (multi-gauge design, compensating lateral-force effects)
FT_33_Sensor Selection Guide