E41-051 · Other Selection · Hydraulic Jack · ★★
After use, the jack slowly leaks hydraulic oil from the piston rod, and the lifting force drops from 30 tons to 28 tons. After standing overnight, oil stains appear on the floor.
The O-ring installation groove depth was poorly designed, giving the seal a compression ratio of only 8%. The standard requires: static-seal compression ratio 15~25%, dynamic-seal compression ratio 12~18%. Per GB/T 3452.3-2005, with an O-ring cross-section diameter d2=3.55mm and groove depth h=3.27mm (for a static seal)→compression ratio ε=(d2-h)/d2×100%=(3.55-3.27)/3.55×100%=7.9%, far below the 15% minimum. The seal contact pressure is insufficient, and high-pressure oil (70MPa) seeps through micro-gaps along the sealing surface. In addition, the groove is machined roughly (Ra=3.2μm, required Ra≤1.6μm), and the microscopic unevenness forms leakage channels.
① Compression-ratio calculation: ε=(d₂-h)/d₂×100%, where d₂ is the O-ring cross-section diameter and h is the groove depth
② Static seal ε=15~25%, dynamic seal ε=12~18% (reciprocating motion), rotary seal ε=5~10%
③ In this case d₂=3.55mm, requiring h=3.55×(1-0.15)=3.02mm (taking a 15% compression ratio)
④ Groove width: b=1.15×d₂=4.08mm (standard recommendation)
⑤ Groove surface roughness: bottom face Ra≤1.6μm, side faces Ra≤3.2μm
⑥ O-ring material: for 70MPa high pressure choose polyurethane (PU) or fabric-reinforced nitrile rubber (high-pressure resistant, extrusion resistant)
⑦ Safety criterion: the working pressure at the seal ≤ the O-ring material's maximum allowable working pressure (add a backup ring to prevent extrusion)
FT_Seal Design Manual