E41-052 · Other Selection · Large Mixer Output Shaft · ★★★
After half a year of operation, the motor-to-reducer joint rolled the key (the key rolled within the keyway), the keyway deformed severely, the clearance between key and keyway reached 1mm, and the output shaft rotated relative to the coupling.
An A-type parallel key 14×9×80mm (GB/T 1096) was selected, transmitting torque T=2000Nm with shaft diameter d=50mm. Bearing stress check: σp=4T/(d×h×L)=4×2000/(0.05×0.009×0.08)=8888889Pa=8.9MPa? That is incorrect. Correct calculation: σp=4T/(d×h×L)=4×2000/(0.05×0.009×0.08)=4×2000/(3.6×10⁻⁵)=222.2MPa. The allowable bearing stress of the 45 steel parallel key is [σp]=120MPa (static load) or 90MPa (light shock); the actual 222.2MPa far exceeds the allowable value, a ratio of 222/90=2.47.
① Parallel key bearing stress check: σp=4T/(d×h×L) ≤ [σp]
② [σp]=90MPa (light shock), σp=4×2000/(0.05×0.009×0.08)=222MPa > 90MPa ❌
③ Improvement options:
a) Increase the key size: select 20×12×90mm, σp=4×2000/(0.05×0.012×0.09)=148MPa → still over the limit
b) Use two keys (180° apart): calculated at 1.5 times the capacity of a single key → required σp=148/1.5=99MPa, close to the allowable value
c) Switch to a spline joint (involute spline; its load capacity is 3~5 times that of a parallel key and fully meets the requirement)
d) Increase the shaft diameter to 60mm: σp=4×2000/(0.06×0.012×0.09)=123MPa → two keys are still required
④ Fastening method: use stepped keys for the two keys or a drive-fit interference fit
FT_Machine Design Handbook