E41-303 · Other Selection · Large Fan Clamping-Sleeve Connection · ★★★★
The shaft-hub connection of a large fan (power 250kW) uses a clamping sleeve (model Z2-100×145), which slipped axially at full load, with a relative shaft-hub displacement of about 5mm.
The clamping sleeve Z2-100×145 (inner diameter 100mm, outer diameter 145mm, length 100mm) transmits a torque T=5000Nm and an axial force F_a=2000N (fan axial thrust). The rated transmission torque of the clamping sleeve is 3900Nm and the rated axial force 1560Nm. The actual torque 5000Nm>3900Nm and the actual axial force 2000N>1560N both exceed the rated values. The clamping sleeve slipped under overload; after slipping, the contact surfaces wore and the friction coefficient dropped from 0.15 to 0.10, further reducing transmission capacity. After the cumulative slip reached about 5mm, the relative position of shaft and hub changed, causing interference between the fan impeller and the casing. Once the mating surfaces of the clamping sleeve wore, disassembly became more difficult (corrosion seizing), requiring a hydraulic puller.
① Clamping-sleeve selection: T_rated ≥ T_actual × SF (SF≥1.5)\n② Also check the axial force: F_a_rated ≥ F_a_actual × SF\n③ In this case select one size larger: Z2-110×155 (T_rated=5300Nm, F_a=2120N)\n④ Set the installation torque per the manufacturer's specification (Z2-100×145 tightening torque 180Nm)\n⑤ Perform a torque test after installation (lock the bolts with a torque wrench, then make a rotation mark to check for slip)