E41-315 · Other Selection · Equipment Lifting Lug · ★★★★★
During the lifting of a large piece of equipment (weight 30t), the lifting-lug weld suddenly tore and the equipment fell. The lifting-lug weld leg height was 8mm (design 10mm), and the weld inspection was unqualified.
The lifting-lug plate (Q345B, thickness 30mm) was joined to the equipment shell (Q345B, thickness 20mm) by fillet welds, with a design weld leg height of 10mm and an effective weld height of 7mm (excluding penetration). The actual leg height was 8mm and the effective weld height 5.6mm. The total weld length is L=2×(100+80)=360mm. The weld load-bearing area is A=L×h_eff×0.7=360×5.6×0.7=1411mm². With a lifting load of 300kN and a dynamic load factor of 1.1, the design load is 330kN. The weld shear stress is τ=F/A=330000/1411≈234MPa. The allowable weld shear stress is [τ]=0.6×σ_s/SF=0.6×345/2.5=82.8MPa (Q345B yield strength 345MPa, safety factor 2.5). The actual stress of 234MPa far exceeds the allowable value of 82.8MPa, so the weld tore instantly during lifting. The lifting-lug design did not check the weld strength per the code, and the weld inspection also failed to detect the insufficient leg height.
① Check the lifting-lug weld strength: τ=F/A ≤ [τ]=0.6×σ_s/SF (SF≥2.5)\n② Set the weld leg height to the design value, with an allowable deviation ≤1mm\n③ Perform 100% magnetic-particle testing (MT) or ultrasonic testing (UT) on the lifting-lug welds\n④ After the lifting lug is fabricated, carry out a load test at 1.25 times the rated load\n⑤ Have the lifting-lug design calculated by qualified personnel, and issue a lifting plan