E41-465 · Other Selection · Receiver Safety Valve Not Calibrated · ★★★★★
The safety valve of a compressed-air receiver (volume 10 m³, design pressure 1.0 MPa) failed to open when the receiver was overpressured (set opening pressure 1.05 MPa); receiver pressure rose to 1.2 MPa (20% above design pressure).
The safety valve (spring direct-loaded type, DN50, set pressure 1.05 MPa) was not calibrated annually as required after installation. After 3 years of use, the spring underwent stress relaxation from fatigue and corrosion (moisture in compressed air) (spring relaxation), and its set pressure drifted from 1.05 MPa to about 1.2 MPa (up 14%). At receiver pressure 1.2 MPa the safety valve still did not open (actual set value had drifted). The air compressor auto-stops at 1.0 MPa, but the pressure switch failed (contact welding), so the compressor kept running and receiver pressure climbed to 1.2 MPa. The safety valve did not act, and the receiver operated at 20% overpressure, creating explosion risk. A pressure vessel overpressured by more than 10% is a serious safety hazard (GB 150 requires the safety valve to relieve overpressure).
① Calibrate the safety valve once a year (verify set pressure and seat tightness).\n② Inspect the pressure vessel periodically (external inspection annually, internal every 3–6 years).\n③ Provide dual protection by pressure switch and safety valve (safety valve still protects if the pressure switch fails).\n④ Add an electric-contact pressure gauge (overpressure alarm + auto-stop; alarm at 0.9 MPa, stop at 1.0 MPa).\n⑤ Use a pilot-operated safety valve (high set-pressure accuracy, little affected by back pressure, long life).