Steel-structure canopy collapse under snow overload (heavy snow)

E41-469 · Other Selection · Canopy Steel Structure Snow Collapse · ★★★★★

Problem Description

A factory steel canopy (span 12 m, length 30 m) collapsed after heavy snow, snow about 30 cm deep. The canopy steel structure was designed without considering snow load.

Root Cause

The canopy is a light steel structure (H-beam, section 300×150 mm, spacing 3 m). The design considered only self-weight plus wind load, not snow load per GB 50009-2012 Load Code for Building Structures. In this region the 50-year return basic snow pressure S_0 = 0.4 kN/m²; 30 cm snow corresponds to snow pressure S = 0.4 kN/m² (snow density about 150 kg/m³, 30 cm → 0.45 kN/m² ≈ 0.4 kN/m²). Roof area 360 m², total snow load = 360×0.4 = 144 kN ≈ 14.7 t. The allowable bending moment of the H300×150 beam (Q235) is M_max = W×[σ] = 490×10³×215 ≈ 105 kNm. Snow-load moment M = q×L²/8 = 3.6×12²/8 = 64.8 kNm (q = 0.4 kN/m²×3 m = 1.2 kN/m + self-weight 0.5 kN/m = 1.7 kN/m×2.1 ≈ 3.6 kN/m? Actually total uniform load of snow plus self-weight is about 4 kN/m). 4×12²/8 = 72 kNm < 105 kNm, strength adequate. But equipment piled on the canopy (about 30 t) plus snow load (only 14.7 t) gave total about 45 t, far exceeding design. Actual collapse cause: miscellaneous items stored long-term on the canopy (about 30 t), snow load only 14.7 t, total 44.7 t; under 44.7 t the steel beam stress exceeded the limit, mid-span deflection exceeded standard (about 80 mm), and bolted joints tore under excessive deformation, collapsing the structure.

Corrective Solution

① The canopy design must consider snow load (per local basic snow pressure in GB 50009).\n② Strictly prohibit storing items on the canopy (adds extra load).\n③ Clear roof snow promptly in heavy snow (clear once depth > 10 cm).\n④ Inspect the steel structure regularly (annually; check bolt loosening, corrosion, deformation).\n⑤ Add displacement monitoring at critical joints (alarm when deflection > L/300).

Checklist

Reference

FT_Machine Design Handbook

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL