E41-475 · Other Selection · Diaphragm Pump Diaphragm Rupture · ★★★★
After 6 months a pneumatic diaphragm pump (aluminum alloy body, PTFE diaphragm) ruptured its diaphragm; the transferred sulfuric acid (30%) leaked and corroded the pump body and floor.
The pump diaphragm (PTFE + EPDM composite, 1.5 mm thick) undergoes bending fatigue under long-term alternating pressure (0–0.6 MPa, about 120 cycles/min). PTFE bending-fatigue life about 10⁶ cycles (at 0.6 MPa difference); over 6 months about 3.1×10⁶ cycles (120 cycles/min×60 min×24 h×180 days ≈ 3.1×10⁶ cycles), exceeding PTFE fatigue life by about 3×. Micro-cracks initiate at the bending stress-concentration region (edge clamp), propagate, and the diaphragm ruptures. Sulfuric acid (30%) enters the drive chamber through the rupture and corrodes the aluminum alloy body (aluminum alloy corrodes rapidly in sulfuric acid, rate about 5 mm/year). Within 1 h of rupture the body is perforated by corrosion and acid leaks.
① Replace the diaphragm periodically (per manufacturer life, generally 6–12 months).\n② Upgrade diaphragm material: PTFE+EPDM → PTFE+TPE (2× fatigue life).\n③ Diaphragm rupture detection: fit a pressure switch in the diaphragm chamber (alarm on abnormal pressure at rupture).\n④ Upgrade pump-body material: aluminum alloy → polypropylene (PP, sulfuric-acid resistant).\n⑤ Equip the pump with a leak collection pan (contain leak spread).
FT_Machine Design Handbook